Created on 11/07/2016
c
2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 1 of 2
MODEL
SCCB
Atmospherically referenced, direct-acting sequence valve with reverse flow
check
SERIES 1 / CAPACITY: 60 L/min. / CAVITY: T-13A
Atmospherically referenced, direct-acting sequence valves with reverse-flow check will supply a secondary circuit
with flow once the pressure at the inlet (port 1) has exceeded the valve setting. Additionally, these valves
incorporate an integral check valve to provide reverse flow from port 2 (sequence) to port 1 (inlet). The pressure
setting of this sequence valve controls the pressure at port 1 relative to the atmospheric vent.
TECHNICAL DATA
Cavity T-13A
Series 1
Capacity 60 L/min.
Factory Pressure Settings Established at 30 cc/min.
Maximum Operating Pressure 350 bar
Response Time - Typical 2 ms
Maximum Valve Leakage at Reseat 0,7 cc/min.
Check Cracking Pressure 2,8 bar
Adjustment - Number of Clockwise Turns to Increase Setting 5
Valve Hex Size 22,2 mm
Valve Installation Torque 41 - 47 Nm
Adjustment Screw Internal Hex Size 4 mm
Locknut Hex Size 15 mm
Locknut Torque 9 - 10 Nm
Seal kit - Cartridge Buna: 990010007
Seal kit - Cartridge Polyurethane: 990010002
Seal kit - Cartridge Viton: 990010006
Model Weight 0.21 kg.
(L)CONTROL
L Standard Screw Adjustment
C Tamper Resistant - Factory Set
(A)ADJUSTMENT RANGE
A 500 - 3000 psi (35 - 210 bar), 1000 psi
(70 bar) Standard Setting
B 300 - 1500 psi (20 - 105 bar), 1000 psi
(70 bar) Standard Setting
C 2000 - 6000 psi (140 - 420 bar), 2000
psi (140 bar) Standard Setting
D 200 - 800 psi (14 - 55 bar), 400 psi (28
bar) Standard Setting
E 100 - 400 psi (7 - 28 bar), 200 psi (14
(N)SEAL MATERIAL
N Buna-N
V Viton
MATERIAL/COATING
Standard Material/Coating
/LH Mild Steel, Zinc-Nickel
snhy.com/SCCB
Model Code Example: SCCBLANCONFIGURATION OPTIONS
Created on 11/07/2016
c
2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 2 of 2
E 100 - 400 psi (7 - 28 bar), 200 psi (14
bar) Standard Setting
W 800 - 4500 psi (55 - 315 bar), 1000 psi
(70 bar) Standard Setting
TECHNICAL FEATURES
Suitable for use in load holding applications.
Atmospherically referenced valves should only be used where it is impossible have a drain connection. Over time, the atmospherically referenced valves may leak
externally or allow moisture into the spring chamber.
Approximately 1 drop (0,07 cc) of fluid will pass into the vented spring chamber every 4000 cycles.
Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge
machining variations.
PERFORMANCE CURVES